| Each system is shipped with a standard 8” forming plate made from 304-Stainless Steel.
Pulsed Hydraulics provides three versions of its Hundred Series Mixers:
| PHi 100 |
1/2” valve opening |
Requires 2-3 hp
compressor
(4-11 scfm)
at 4 pulses/minute |
Enclosure size (H x W x D)
16” x 14” x 6.25” |
| PHi 200 |
3/4” valve opening |
Requires 2-4 hp
compressor
(9-25 scfm)
at 4 pulses/minute |
Enclosure size (H x W x D)
16” x 14” x 6.25” |
| PHi 300 |
1” valve opening |
Requires 3-7 hp
compressor
(17-43 scfm)
at 4 pulses/minute |
Enclosure size (H x W x D)
20” x 18” x 9” |
The PHi 100 Mixer is ample to mix a cylindrical wet-well of up to 6,000 gallons with a diameter of 10 ft. or less. Larger and different shaped wet-wells may require the PHi 200 or 300 mixers.
Power consumption from PHi systems including internal heater, is less than 150W @ 110VAC. (Power consumption of the compressor is determined by application.)
System adjustments:
| Pulse duration |
10ths of a second (normal operation 0.3-0.6 seconds) |
| Pulse rate |
Normal operation 3-8 pulses per minute |
| Input air pressure |
Typical 100 psi |
| Output air pressure |
Typical operation 40-60 psig |
Round wet-wells more than 10 feet in diameter, rectangular wet-wells more than 8 feet by 8 feet, and irregular shaped wet-wells may require more than one plate. Provide plan-view drawing to your representative to determine actual requirements.
PHi’s mixing systems are covered by U.S. patents numbers 7,282,141 B2 and 7,374,675 B2, with
others pending.
|